Abstract

The natural convection heatsink is the most commonly used cooling device, especially for high-power LED lights, because of its reliability and low long-term cost. High power LED lights are generally used in an inclined configuration for street lamps and security lamps. However, it was difficult to estimate the thermal performance of an inclined heatsink, because the results from previous studies are not applicable to the inclined configuration. In this study, we measured the thermal performance of an inclined cylindrical heatsink with plate fins. Various fin numbers, fin heights, base temperatures, and inclination angles (30° and 60°) were examined. Based on the experimental results, the Nusselt number correlation is presented. This correlation is applicable when the Rayleigh number, ratio of the fin height to cylinder diameter, and fin number are in the ranges 100,000 600,000, 1/6 1/2, and 9-72, respectively. - -