Abstract

In the work study results of influence of typical working junction angle on amount changing of local aerodynamic resistances when air flows in different directions is represented. Using finite-element software, aerodynamic parameters of elements of mine ventilation network is obtained and is compared with analytical calculations Interinfluence local aerodynamic resistances located at ventilation network consecutively in normal and reversing behavior is discovered. It allows to increase accuracy of calculation of mine ventilation network at emergency ventilation operation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.