Year
Publisher
Journal
Institution
1
Institution Country
Publication Type
Field Of Study
Topics
Open Access
Language
Filter 1
Year
Publisher
Journal
Institution
1
Institution Country
Publication Type
Field Of Study
Topics
Open Access
Language
Filter 1
Export
Sort by: Relevance
Hyponatremia and Fever in a Patient on Ipilimumab and Nivolumab (Immune Checkpoint Inhibitors): A Case Report.

Immune checkpoint inhibitors (ICIs) are novel anticancer therapy approved in multiple tumors and their use is rapidly increasing. They are associated with various systemic side effects that are immune-mediated and clinically coined as “immune-related adverse effects” (irAE). Hyponatremia is a possible side effect in patients receiving ICIs. Fever is another side effect that is mostly non-infectious. There are different mechanisms leading to hyponatremia in patients on ICIs, which could be (1) hypovolemic hyponatremia due to hemodynamic disturbance secondary to volume depletion (eg, from irAE like colitis and enteritis) or hypervolemia due to congestive heart failure, cirrhosis, or nephrosis; (2) syndrome of inappropriate antidiuretic hormone (SIADH) secretion (especially from underlying lung cancer or neurological irAE like encephalitis and meningitis) with elevated urine sodium and urine osmolarity; and (3) irAE-related endocrinopathies such as hypophysitis, adrenal insufficiency, and hypothyroidism leading to euvolemic hyponatremia. We describe an interesting case of hyponatremia and fever in a patient receiving Ipilimumab and Nivolumab. The possible etiology of hyponatremia, in this case, was hypovolemia and volume depletion secondary to fever.

Read full abstract
Open Access
Intravenous Smart Pump Drug Library Compliance: A Descriptive Study of 44 Hospitals.

Although intravenous (IV) smart pumps with built-in dose-error reduction systems (DERS) can reduce IV medication administration error, most serious adverse events still occur during IV medication administration. Sources of error include overriding DERS and manually bypassing drug libraries and the DERS. Our purpose was to use the Regenstrief National Center for Medical Device Informatics data set to better understand IV smart pump drug library and DERS compliance. Our sample consisted of 12 months of data from 7 hospital systems, 44 individual hospitals, and descriptive data from the American Hospital Directory (AHD) for 2015. The aims of the study were (1) to determine whether there are differences in IV smart pump drug library compliance between hospital systems and (2) to provide a broad descriptive overview of relevant trends related to IV smart pump compliance. For aim 1, we found 3 significant relationships among the 7 hospital systems: systems 3 (P < 0.001), 6 (P = 0.003), and 7 (P = 0.002) had significantly higher IV smart compliance as compared with system 4. For aim 2, the number of drug library profiles was positively correlated (P = 0.029) with IV smart pump compliance and the IV smart pump type used was significantly correlated (P = 0.013) with IV smart pump compliance. Our findings support that there are differences in IV smart pump compliance both within and between hospital systems and that IV smart pump type and the number of drug library profiles may be influencing factors. Further research is required to more accurately identify the impact of these factors in this very important area of patient safety.

Read full abstract
The H-Wave® device is an effective and safe non-pharmacological analgesic for chronic pain: a meta-analysis

This meta-analysis was conducted to systematically review the efficacy and safety of the H-Wave (Electronic Waveform Lab, Inc, Huntington Beach, CA, USA) device and programme as a non-pharmacological analgesic treatment in chronic soft tissue inflammation and neuropathic pain. Five studies related to pain relief, reduction in pain medication and increased functionality obtained with the H-Wave device were included in the analysis. Data were analysed using the random effects model, including adjustment to evaluate variability, size of study and bias in effect size. A total of 6535 participants were included in the meta-analysis; there were 8065 participants' outcomes measured due to multiple measurements per participant. The H-Wave device decreased pain ratings across various chronic soft tissue inflammation and neuropathic pain conditions. The mean weighted effect size was 0.59, and the estimated effect size variance was 0.00003 (95% confidence intervals [CI]: 0.580, 0.600). The H-Wave device also decreased the intake of pain medication in patients with various chronic soft tissue inflammation and neuropathic pain conditions. The mean weighted effect size was 0.56, and the estimated effect size variance was 0.000013 (95% CI: 0.553, 0.567). Patient functionality was also improved with use of the H-Wave device. The mean weighted effect size was 0.70, and the estimated effect size variance was 0.00002 (95% CI: 0.691, 0.709). A chi-square test for homogeneous effect sizes found highly significant (P<0.00001) variability, indicating a robust significant effect size for increased functionality relative to both pain relief and reduction in pain medication. There was little to no evidence of any adverse effects associated with the use of the H-Wave device. The findings indicate a moderate to strong effect of the H-Wave device in providing pain relief, reducing the requirement for pain medication and increasing functionality. The most robust effect was observed for improved functionality, suggesting that the H-Wave device may facilitate a quicker return to work and other related daily activities.

Read full abstract