Total ozone data available from the World Ozone and Ultraviolet Radiation Data Centre (WOUDC) have been compared with Version 7 of the Nimbus 7 (for the 1978–1993 period) and Meteor 3 total ozone mapping spectrometer (TOMS) data sets (for the 1991–1994 period) and with Version 6 of the Nimbus 7 solar backscattered ultraviolet (SBUV) data set (for the 1978–1990 period). Comparison between the ground‐based and satellite observations resulted in parameters such as bias, scattering, relative trend, and seasonal component. About 80% of all Dobson, Brewer, and filter ozonometer stations have standard deviations of monthly mean differences with TOMS that are less than 2.5%. Typically, results of the comparisons between ground‐based stations and SBUV are similar to those for ground‐based and TOMS comparisons. For the ground‐based direct sun total ozone measurements the standard deviations between TOMS and Dobson daily mean values are about 2.4%. The standard deviations for Brewer and filter ozonometer stations are 2.2 and 3.5%, respectively. For the less accurate zenith sky measurements, standard deviations are 3.8% for Dobsons, 4% for Brewers, and 4.7% for filter ozonometer data. Comparisons of individual ground‐based measurements with satellite overpasses yield standard deviations which for middle latitudes increase approximately linearly from about 2% at coincidence to 6% for a 24 hour difference in time or a 600 km spatial difference. Typical problems with ground‐based observations and results of the comparisons for individual stations are also discussed.
Read full abstract