Over the past few decades, anabolic androgenic steroids (AASs) have been abused in and out of competition for their performance-enhancing and muscle-building properties. Traditionally, AASs were commonly detected using gas chromatography-mass spectrometry in the initial testing procedure for doping control purposes. Gas chromatography-Orbitrap high-resolution mass spectrometry (GC-Orbitrap-HRMS) is a new technology that has many advantages in comparison with GC-MS (e.g., a maximum resolving power of 240,000 (FWHM at m/z 200), excellent sub-ppm mass accuracy, and retrospective data analysis after data acquisition). Anti-doping practitioners are encouraged to take full advantage of the updated techniques of chromatography-mass spectrometry to develop sensitive, specific, and rapid screening methods for AASs. A new method for screening a wide range of AASs in human urine using GC-Orbitrap-HRMS was developed and validated. The method can qualitatively determine 70 anabolic androgenic steroids according to the minimum required performance limit of the World Anti-Doping Agency. Moreover, the validated method was successfully applied to detect six metabolites in urine after the oral administration of metandienone, and their excretion curves in vivo were studied. Metandienone M6 (17β-hydroxymethyl-17α-methyl-18-nor-androst-1,4,13-trien-3-one) has been identified as a long-term urinary metabolite which can be detected up to 7 weeks, thus providing a longer detection window compared with previous studies. This study provides a rationale for GC-Orbitrap-HRMS in drug metabolism and non-targeted screening.