The Transcatheter Valve Therapy Registry was queried for TAVR procedures using transaxillary and transcarotid access between July 2015 and June 2021. Patients received a self-expanding Evolut R, PRO, or PRO+valve (Medtronic) and had 1-year follow-up. Thirty-day and 1-year outcomes were compared in transcarotid and transaxillary groups after 1:2 propensity score-matching. Multivariable regression models were fitted to identify predictors of key end points. The propensity score-matched cohort included 576 patients receiving transcarotid and 1142 receiving transaxillary access. Median procedure time (99 vs 118 minutes; P<.001) and hospital stay (2 vs 3days; P<.001) were shorter with transcarotid versus transaxillary access. At 30days, patients with transcarotid access had similar mortality (Kaplan-Meier estimates 3.7% vs 4.3%, P=.57) but significantly lower stroke (3.1% vs 5.9%; P=.017) and mortality or stroke (6.0% vs 8.9%; P=.033) compared with patients receiving transaxillary access. Similar differences were observed at 1year. Transaxillary access was associated with increased risk of 30-day stroke (hazard ratio, 2.14; 95% confidence interval, 1.27-3.58) by multivariable regression analysis. Transcarotid versus transaxillary access for TAVR using a self-expanding valve is associated with procedural benefits and significantly lower stroke and mortality or stroke at 30days. In patients with unsuitable femoral anatomy, transcarotid access may be the preferred delivery route for self-expanding valves.
Read full abstract