Microphysiological system (MPS), a new technology for invitro testing platforms, have been acknowledged as a strong tool for drug development. In the central nervous system (CNS), the blood‒brain barrier (BBB) limits the permeation of circulating substances from the blood vessels to the brain, thereby protecting the CNS from circulating xenobiotic compounds. At the same time, the BBB hinders drug development by introducing challenges at various stages, such as pharmacokinetics/pharmacodynamics (PK/PD), safety assessment, and efficacy assessment. To solve these problems, efforts are being made to develop a BBB MPS, particularly of a humanized type. In this study, we suggested minimal essential benchmark items to establish the BBB-likeness of a BBB MPS; these criteria support end users in determining the appropriate range of applications for a candidate BBB MPS. Furthermore, we examined these benchmark items in a two-dimensional (2D) humanized tricellular static transwell BBB MPS, the most conventional design of BBB MPS with human cell lines. Among the benchmark items, the efflux ratios of P-gp and BCRP showed high reproducibility in two independent facilities, while the directional transports meditated through Glut1 or TfR were not confirmed. We have organized the protocols of the experiments described above as standard operating procedures (SOPs). We here provide the SOPs with the flow chart including entire procedure and how to apply each SOP. Our study is important developmental step of BBB MPS towards the social acceptance, which enable end users to check and compare the performance the BBB MPSs.
Read full abstract