In combination with the author's experiences in design for integrated unit for natural gas field gathering and transmission, this paper describes conventional practices and technical characteristics of integrated unit in the processes of standardization design and modularization establishment and analyzes the initial application of pneumatic control ball valve, wedge-shaped flowmeter and other new technologies for surface facilities in the gas field. As a result, a new design idea is proposed in this paper, i.e., to improve the integration level of surface facilities, to minimize power consumption and maintenance works and to realize unattended work mode.