The image-derived input function (IDIF) from the descending aorta has demonstrated performance comparable to arterial blood sampling while avoiding its invasive nature in parametric imaging. However, in conventional PET, large vessels may not always be within the imaging field of view (FOV). This study aims to evaluate the efficacy of dynamic parametric Ki imaging using image-derived input functions (IDIFs) extracted from various arteries, facilitated by total-body PET/CT. Twenty-three participants underwent a 60-minute total-body [18F]FDG PET scan. Data from each subject were used to reconstruct both total-body PET images and short-axis field-of-view PET images at different bed positions, each with a 25cm axial field-of-view (AFOV). Partial volume correction (PVC) was performed using the blurred Van Cittert iterative deconvolution. IDIFs extracted from the descending aorta, carotid artery, abdominal aorta, and iliac artery were employed for Patlak analysis. The resulting Ki images were compared using quantification indicators and subjective assessment. Linear regression analysis was conducted to examine the correlation of Ki values among IDIFs in normal organ and lesion regions of interest (ROIs). High similarities were observed in Ki images derived from the IDIFs from the descending aorta and other arteries, with a median structural similarity index measure (SSIM) above 0.98 and a median peak signal-to-noise ratio (PSNR) above 37dB. Linear regression analysis revealed strong correlations in Ki values (r² > 0.88) between the descending aorta and the three alternative vessels, with slopes of the linear fits close to 1. No significant difference in lesion detectability among IDIFs was found, as assessed visually and using metrics such as tumor-to-background ratio (TBR) and contrast-to-noise ratio (CNR) (P < 0.05). IDIFs from smaller vessels can reliably reconstruct parametric Ki images without compromising lesion detectability, providing clinically relevant information.
Read full abstract