HomeRadiologyVol. 263, No. 3 Previous CommunicationsLetters to the EditorLow-Dose Scan Protocols in Dual-Source CT Coronary AngiographyMin Li, Gang SunMin Li, Gang SunAuthor AffiliationsDepartment of Medical Imaging, Jinan Military General Hospital, 25 Shifan Rd, Jinan, Shandong, China 250031 e-mail: [email protected]Min LiGang SunPublished Online:Jun 1 2012https://doi.org/10.1148/radiol.12112369MoreSectionsFull textPDF ToolsImage ViewerAdd to favoritesCiteTrack CitationsPermissionsReprints ShareShare onFacebookTwitterLinked In References1 Neefjes LA, Dharampal AS, Rossi Aet al.. Image quality and radiation exposure using different low-dose scan protocols in dual-source CT coronary angiography: randomized study. Radiology 2011;261(3):779–786. Link, Google Scholar2 Weustink AC, Mollet NR, Pugliese Fet al.. Optimal electrocardiographic pulsing windows and heart rate: effect on image quality and radiation exposure at dual-source coronary CT angiography. Radiology 2008;248(3):792–798. Link, Google Scholar3 Hurwitz LM, Reiman RE, Yoshizumi TTet al.. Radiation dose from contemporary cardiothoracic multidetector CT protocols with an anthropomorphic female phantom: implications for cancer induction. Radiology 2007;245(3):742–750. Link, Google Scholar4 Einstein AJ, Elliston CD, Arai AEet al.. Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner. Radiology 2010;254(3):698–706. Link, Google Scholar5 Huda W. Computing effective doses from dose-length product in CT. Radiology 2008;248(1):321; author reply 321–322. Link, Google ScholarArticle HistoryPublished online: June 2012Published in print: June 2012 FiguresReferencesRelatedDetailsCited ByComputed Tomography in Adult Congenital Heart DiseasePraveenRanganath, SatinderSingh, SuhnyAbbara, Prachi P.Agarwal, PrabhakarRajiah2019 | Radiologic Clinics of North America, Vol. 57, No. 1Radiation dose and diagnostic accuracy of high-pitch dual-source coronary angiography in the evaluation of coronary artery stenosesM.Koplay, H.Erdogan, A.Avci, M.Sivri, K.Demir, I.Guler, L.S.Demir, Y.Paksoy2016 | Diagnostic and Interventional Imaging, Vol. 97, No. 4Questionnaire Survey of SPECT Studies after the Supply Shortage of Tc-99m and Model Analysis Concerning Earnings and Expenditure of Generator UseRyoKINOSHITA, ShigeruKOSUDA, KatsumiKOIKE, TakashiARAI2012Jan1 | RADIOISOTOPES, Vol. 61, No. 12Recommended Articles Imaging the Infant Chest without Sedation: Feasibility of Using Single Axial Rotation with 16-cm Wide-Detector CTRadiology2017Volume: 286Issue: 1pp. 279-285Advanced CT Techniques for Decreasing Radiation Dose, Reducing Sedation Requirements, and Optimizing Image Quality in ChildrenRadioGraphics2019Volume: 39Issue: 3pp. 709-726The Effect of Contrast Material on Radiation Dose at CT: Part II. A Systematic Evaluation across 58 Patient ModelsRadiology2017Volume: 283Issue: 3pp. 749-757Atrial Fibrillation: Diagnostic Accuracy of Coronary CT Angiography Performed with a Whole-Heart 230-µm Spatial Resolution CT ScannerRadiology2017Volume: 284Issue: 3pp. 676-684Next-Generation Hardware Advances in CT: Cardiac ApplicationsRadiology2020Volume: 298Issue: 1pp. 3-17See More RSNA Education Exhibits Demystifying the CT Dose Sheet and Image HeadersDigital Posters2020Spectrum of Disease in Patients Presenting with Symptoms of Acute and Chronic Arterial Limb Ischemia on CT AngiographyDigital Posters2020Can Superior Visualization CT-Angiography Replace and Overwhelm Conventional Angiography? The Pre-Operative Assessment of Endovascular Treatment with Quarter Millimeter Isotropic Data SetsDigital Posters2019 RSNA Case Collection Takayasu ArteritisRSNA Case Collection2020Cystic adventitial disease of the popliteal arteryRSNA Case Collection2020Subclavian Stenosis with Pre-StealRSNA Case Collection2021 Vol. 263, No. 3 Metrics Altmetric Score PDF download
Read full abstract