Year Year arrow
arrow-active-down-0
Publisher Publisher arrow
arrow-active-down-1
Journal
1
Journal arrow
arrow-active-down-2
Institution Institution arrow
arrow-active-down-3
Institution Country Institution Country arrow
arrow-active-down-4
Publication Type Publication Type arrow
arrow-active-down-5
Field Of Study Field Of Study arrow
arrow-active-down-6
Topics Topics arrow
arrow-active-down-7
Open Access Open Access arrow
arrow-active-down-8
Language Language arrow
arrow-active-down-9
Filter Icon Filter 1
Year Year arrow
arrow-active-down-0
Publisher Publisher arrow
arrow-active-down-1
Journal
1
Journal arrow
arrow-active-down-2
Institution Institution arrow
arrow-active-down-3
Institution Country Institution Country arrow
arrow-active-down-4
Publication Type Publication Type arrow
arrow-active-down-5
Field Of Study Field Of Study arrow
arrow-active-down-6
Topics Topics arrow
arrow-active-down-7
Open Access Open Access arrow
arrow-active-down-8
Language Language arrow
arrow-active-down-9
Filter Icon Filter 1
Export
Sort by: Relevance
  • Research Article
  • Cite Count Icon 1
  • 10.1177/09544119241244537
A novel design of hip-stem with reduced strain-shielding.
  • Apr 21, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Tanmoy Loha + 3 more

The use of uncemented stems in hip arthroplasty has been increasing, even in osteoporotic patients. The major concerns of uncemented hip-stems, however, are peri-prosthetic fracture, thigh pain, and proximal femoral stress-/strain-shielding. In this study, a novel design of uncemented hip-stem is proposed that will reduce such concerns, improve osseointegration, and benefit both osteoporotic and arthritic patients. The stem has a central titanium alloy core surrounded by a set of radial buttresses that are partly porous titanium, as is the stem tip. The aim of the study was to investigate the mechanical behaviour of the proposed partly-porous design, examining load transfer in the short-term, and comparing its strain-shielding behaviour with a solid metal implant. The long-term effect of implant-induced bone remodelling was also simulated. Computed tomography based three-dimensional finite element models of an intact proximal femur, and the same femur implanted with the proposed design, were developed. Peak hip contact and major muscle forces corresponding to level-walking and stair climbing were applied. The proposed partly-porous design had approximately 50% lower strain-shielding than the solid-metal counterpart. Results of bone remodelling simulation indicated that only 16% of the total bone volume is subjected to reduction of bone density. Strain concentrations were observed in the bone around the stem-tip for both solid and porous implants; however, it was less prominent for the porous design. Lower strain-shielding and reduced bone resorption are advantageous for long-term fixation, and the reduced strain concentration around the stem-tip indicates a lower risk of peri-prosthetic fracture.

  • Research Article
  • 10.1177/09544119241244513
Prediction of excess cement residues using a regression model to avoid peri-implant diseases: An in vitro study.
  • Apr 16, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Febina Josephraj + 2 more

Dental implant restorations attached to cement can potentially result in peri-implant mucositis and peri-implantitis if cement residues are present. Effectively predicting and eliminating such dental cement residues is crucial for preventing complications. This study focuses on creating a regression model using the pixel values to predict the Excess Cement Residues (ECR) by employing an octagonal surface imaging approach. A model featuring gingival imitation, ten abutments, and ten crowns was created, and the cemented implants underwent thorough photographic and analytical assessment. The ECR was determined through two distinct approaches: the Computerized Planimetric Method (CPM) and the weighing method. Across ten implants in this in vitro study, ECR varied from 0.3 to 21 mg, with an average of 5.69 mg. The findings reveal a higher amount of ECR on the distal, mesiobuccal, and mesial sides. Utilizing Pearson's correlation, a coefficient value of r = 0.786 signifies a strong correlation between CPM and the weighing method. The regression model further aids in predicting ECR based on pixel values. The octagonal surface imaging approach not only vividly captures information about ECR in the implant cementation region but also emphasizes the feasibility of ImageJ as an effective tool for detecting ECR. The congruence between CPM and the weighing method results supports the application of the regression model for precise ECR prediction.

  • Research Article
  • 10.1177/09544119241245503
Experimental investigation on punch shear strength of poly lactic acid specimens for biomedical applications.
  • Apr 16, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Shrutika Sharma + 2 more

The designed biomedical implants require excellent shear strength primarily for mechanical stability against forces in human body. However, metallic implants undergo stress shielding with release of toxic ions in the body. Thus, Fused Deposition Modeling (FDM) has made significant progress in the biomedical field through the production of customized implants. The mechanical behavior is highly dependent on printing parameters, however, the effect of these parameters on punch shear strength of ASTM D732-02 standard specimens has not been explored. Thus, in the current study, the effect of infill density (IFD), printing speed (PTS), wall thickness (WLT), and layer thickness (LYT) has been investigated on the punch shear strength using Response Surface Methodology. The Analysis of Variance (ANOVA) has been performed for predicting statistical model with 95% confidence interval. During the statistical analysis, the terms with p-value lower than 0.05 were considered significant and the influence of process parameters has been examined using microscopic images. The surface plots have been used for discussing the effect of interactions between printing parameters. The statistical results revealed IFD as the most significant contributing factor, followed by PTS, LYT, and WLT. The study concluded by optimization of printing parameters for obtaining the highest punch shear strength.

  • Research Article
  • Cite Count Icon 1
  • 10.1177/09544119241242968
Effect of anterior cruciate ligament injury on acceleration response of knee joint.
  • Apr 9, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Reza Ahmadi + 5 more

This study investigated the effect of anterior cruciate ligament (ACL) injury on relative acceleration of the tibia and femur during a number of tests/activities, in order to assess the feasibility of acceleration-based diagnosis of ACL injury using inertial sensors. First, a detailed finite element model of the knee joint was developed to simulate the target tests/activities, and identify those in which a large difference between the maximum acceleration peaks (MAPs) of the healthy and ACL injured knees is likely to be observed. The promising tests/activities were entered in an experimental study, where the relative accelerations of the tibiae and femurs of 20 individuals with unilateral ACL injury, allocated randomly to two groups of conscious and unconscious test conditions, were recorded. Model predictions indicated MAP ratios>1.5 for the ACL-injured to healthy knees, during the anterior drawer, Lachman, and pivot-shift tests, as well as the lunge activity. The experimental MAP results indicated acceptable test-retest reliabilities for all tests (coefficient of variation<0.25), and significant MAP differences (p < 0.05) in the anterior drawer and pivot-shift tests, in both coconscious and unconscious conditions. The individualized MAP results indicated side-to-side differences>2 m/s2 for all subjects during unconscious pivot shift tests, and >0.5 m/s2 for eight cases out of ten during conscious anterior drawer tests. It was concluded that the pivot shift test had a great repeatability and discriminative ability for acceleration-based diagnosis of ACL injury in unconscious condition. For the conscious condition, however, the anterior drawer test was appeared to be most promising.

  • Research Article
  • 10.1177/09544119241241550
Physics-based in silico modelling of microvascular pulmonary perfusion in COVID-19.
  • Apr 2, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Elizabeth Dimbath + 6 more

Due to its ability to induce heterogenous, patient-specific damage in pulmonary alveoli and capillaries, COVID-19 poses challenges in defining a uniform profile to elucidate infection across all patients. Computational models that integrate changes in ventilation and perfusion with heterogeneous damage profiles offer valuable insights into the impact of COVID-19 on pulmonary health. This study aims to develop an in silico hypothesis-testing platform specifically focused on studying microvascular pulmonary perfusion in COVID-19-infected lungs. Through this platform, we explore the effects of various acinar-level pulmonary perfusion abnormalities on global lung function. Our modelling approach simulates changes in pulmonary perfusion and the resulting mismatch of ventilation and perfusion in COVID-19-afflicted lungs. Using this coupled modelling platform, we conducted multiple simulations to assess different scenarios of perfusion abnormalities in COVID-19-infected lungs. The simulation results showed an overall decrease in ventilation-perfusion (V/Q) ratio with inclusion of various types of perfusion abnormalities such as hypoperfusion with and without microangiopathy. This model serves as a foundation for comprehending and comparing the spectrum of findings associated with COVID-19 in the lung, paving the way for patient-specific modelling of microscale lung damage in emerging pulmonary pathologies like COVID-19.

  • Research Article
  • 10.1177/09544119241240908
Assessing patient transport conditions during ambulance transit.
  • Apr 1, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Pedro Vitor Uchima + 1 more

Emergency ambulances play a vital role in medical rescue and patient transportation, but their transit can impact patient health due to vehicle dynamic forces and vibrations. This study evaluates patient transport conditions on a stretcher subjected to vertical vibration excitation from road unevenness. Using an eight-degree-of-freedom numerical model, we analyze the construction parameters of a medical stretcher's support and vehicle suspension. Actual experimental data from an emergency vehicle were utilized to assess the vibration conditions experienced by both the stretcher and the ambulance floor. The model is adjusted based on measurements, specifically targeting the main vibration modes. The investigation involves determining temporal responses for vertical accelerations and characterizing vibration modal parameters under various transportation conditions. Notably, several system natural frequencies fall within the range of human body frequencies, making them susceptible to mechanical excitation, particularly in the human neck, abdomen, and spine. A sensitivity analysis underscores the influence of medical stretcher support structure parameters on patient comfort. Increasing support stiffness, which alters the stretcher's natural frequency, and damping coefficient reduce vibration propagation between the vehicle and the patient. Additionally, the research predicts the model's dynamic behavior on roads with low-quality pavement, indicating vibrational amplitudes that could potentially be discomforting and unhealthy for individuals. The study illustrates a vibration exposure period on a class E road, revealing that transportation longer than 25 min may cause damage to patient health.

  • Research Article
  • 10.1177/09544119241241440
The effect of different mechanism combinations on sliding between brace and lower limb during walking and leg-raising.
  • Mar 27, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Yuzhou Yan + 5 more

Knee braces are commonly used to support the knee joint and improve function. However, brace sliding caused by the misalignment between brace and knee during motion is a common problem, which reduces the therapeutic effect and leads to brace abandonment. To investigate the effect of mechanism combinations on sliding, an experimental brace was designed to isolate the mechanism as the sole variable. Ten healthy participants were recruited, each of whom worn four combinations of lateral/medial mechanisms: lateral and medial single-axis (SA), lateral super gear (SG) and medial non-circular gear (NCG), lateral four-bar linkage (FL) and medial SG, and lateral FL and medial NCG. The knee flexion angle was collected using inertial measurement units, and brace sliding was measured by 3D motion capture system. All combinations had significant changes in peak sliding of thigh and shank compared to the SA combination (p < 0.05), but lateral FL and medial NCG combination had the lowest peak and final sliding during walking and leg-raising, with significant reductions of 40.7 and 85.3% in peak sliding of thigh, and significant reductions of 56.3 and 72.0% in peak sliding of shank, respectively (p < 0.05). Moreover, the mechanism combination did not significantly impact the knee range of motion (p > 0.05). The mechanism combination that fit the instantaneous center of rotation of lateral/medial condyle of knee joint demonstrates a significant reduction in brace sliding. Additionally, the peak sliding during motion is significantly higher than the final sliding.

  • Research Article
  • 10.1177/09544119241240940
Evaluate the effect of bone density variation on stress distribution at the bone-implant interface using numerical analysis.
  • Mar 27, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Bhargav Hindurao + 3 more

The current study aims to comprehend how different bone densities affect stress distribution at the bone-implant interface. This will help understand the behaviour and help predict success rates of the implant planted in different bone densities. The process of implantation involves the removal of bone from a small portion of the jawbone to replace either a lost tooth or an infected one and an implant is inserted in the cavity made as a result. Now the extent of fixation due to osseointegration is largely dependent on the condition of the bone in terms of the density. Generally, the density of the bone is classified into four categories namely D1, D2, D3, and D4; with D1 being purely cortical and D4 having higher percentage of cancellous bordered by cortical bone. A bone model with a form closely resembling the actual bone was made using 3D CAD software and was meshed using Hyper Mesh. The model was subjected to an oblique load of 120 N at 70° to the vertical to replicate occlusal loading. A finite element static analysis was done using Abaqus software. The stress distribution contours at the bone-implant contact zone were studied closely to understand the changes as a result of the varying density. It was revealed that as the quantity of the cancellous bone increased from D1 to D4 the cortical peak stress levels dropped. The bone density and the corresponding change in the material characteristics was also responsible for the variation in the peak stress and displacement values.

  • Open Access Icon
  • Research Article
  • 10.1177/09544119241238950
Phantom validation of a novel RSA-based impingement metric to assess component-on-component impingement risk.
  • Mar 22, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Shahnaz Taleb + 3 more

Component-on-component impingement in total hip arthroplasty may lead to post-operative complications including dislocation. Despite numerous clinical studies focusing on reducing this risk, assessment methods remain limited to qualitative radiography, finite element analysis, and cadaver studies. There is a need for more precise measurements of impingement in the research setting. We aimed to validate a novel RSA-based impingement metric to measure component-on-component impingement in vivo. A phantom experiment of a standard metal-on-polyethylene total hip system was performed. RSA examinations were performed as typical for a traditional weight-bearing RSA exam for large joints. The phantom was placed in 10 possible impinged positions and one neutral position. Double exposure radiographs were taken to measure repeatability. The closest distance between the skirt of the head and the inner circumference of the acetabular cup liner was measured to assess impingement risk. Distances between the closest point of the hood to the edge of the cup in 10 impinged positions ranged from 0.05 to 1.03 mm, with the average being 0.67 mm. In the neutral position, the distance measured is 11.02 mm. Excellent repeatability was observed, with a standard deviation of 0.03 mm with an r value of 0.09. A validated RSA-based risk metric was established to evaluate in vivo hip impingement. A 1 mm threshold may be proposed to define impingement where distances approaching 1.00 mm are at a greater risk of impingement. This simplified metric holds promise for upcoming clinical studies on component-on-component impingement.

  • Research Article
  • Cite Count Icon 1
  • 10.1177/09544119241239112
Resistance model of an active capsule endoscope in a peristaltic intestine.
  • Mar 22, 2024
  • Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
  • Yi Huang + 3 more

In the past studies, the resistance of magnetically controlled capsules running through the small intestine has been modeled assuming that the small intestine was a circular tube with a constant diameter. Peristalsis is an important character of the human gastrointestinal system, and it would result in some changes in the diameter of the intestine, meaning that the existing resistance models would no longer be applicable. In this paper, based on the assumption that intestinal peristalsis is actually a sinusoidal wave, a resistance model of the capsule running in the peristaltic intestine is established, and then it is validated experimentally. The model provides a realistic foundation for the optimization and control of the magnetically controlled endoscopy.