Year Year arrow
arrow-active-down-0
Publisher Publisher arrow
arrow-active-down-1
Journal
1
Journal arrow
arrow-active-down-2
Institution Institution arrow
arrow-active-down-3
Institution Country Institution Country arrow
arrow-active-down-4
Publication Type Publication Type arrow
arrow-active-down-5
Field Of Study Field Of Study arrow
arrow-active-down-6
Topics Topics arrow
arrow-active-down-7
Open Access Open Access arrow
arrow-active-down-8
Language Language arrow
arrow-active-down-9
Filter Icon Filter 1
Year Year arrow
arrow-active-down-0
Publisher Publisher arrow
arrow-active-down-1
Journal
1
Journal arrow
arrow-active-down-2
Institution Institution arrow
arrow-active-down-3
Institution Country Institution Country arrow
arrow-active-down-4
Publication Type Publication Type arrow
arrow-active-down-5
Field Of Study Field Of Study arrow
arrow-active-down-6
Topics Topics arrow
arrow-active-down-7
Open Access Open Access arrow
arrow-active-down-8
Language Language arrow
arrow-active-down-9
Filter Icon Filter 1
Export
Sort by: Relevance
Preparations for Ultra-High Dose Rate 25-90 MeV Electron Radiation Experiments with a Compact, High-Peak-Current, X-band Linear Accelerator.

The Distributed Charge Compton Source (DCCS) developed by Lumitron Technologies, Inc. has produced a 25-MeV electron beam with 1.7-nC macrobunches at a 100-Hz repetition rate from a compact, high-gradient X-band (11.424 GHz) accelerator. The DCCS is currently being commissioned to produce 100-MeV-class electrons, well within the very high energy electron (VHEE) energy regime, with macrobunch charges of up to 25 nC at repetition rates up to 400 Hz. The DCCS is also designed to produce imaging X rays through Laser Compton scattering. This work aims to describe the preparations for the first dosimetry experimental campaign using this accelerator system at energies ranging from 25 MeV to 90 MeV through hardware development and Monte Carlo (TOPAS) simulation studies. A significant goal of these preparations is to configure the machine so that it can be used to both image with X rays and subsequently treat with VHEEs without movement of the animal model under study. At ultra-high dose rates, this X-ray image-guided electron source could be used to investigate dose-rate dependent differential sparing of normal and malignant biological tissue, known as the FLASH effect. An indium-tin-oxide-coated, 100-μm-thick diamond window was obtained and installed in a custom flange assembly to act as the electron/X-ray vacuum exit window. Simulations at 25 MeV suggest that a scattering foil and collimator can shape the output of the accelerator to produce a 12-mm-diameter, flat-field, circular beam with a 1.7-nC macrobunch charge. This corresponds to an entrance dose of 10 Gy in less than 100 ms. These initial results highly motivate an experimental campaign toward investigating VHEE FLASH using the DCCS at Lumitron Technologies, Inc.

Read full abstract
Just Published Icon Just Published
What's in a Proton FLASH Beam? Characterizing Ultra-High Dose Rate Protons Using a Commercial Plastic Scintillator.

While biological studies of the FLASH effect in proton beams have mainly been performed in the plateau region at maximum beam energy and current, this type of delivery has limited clinical applications. Naturally, it is anticipated that plans to treat patients clinically with FLASH-radiotherapy (FLASH-RT) will capitalize on the Bragg peak. However, as the proton spot widens with depth, the time required to deliver the entire dose to any single point increases. This decreases the dose rate, making the ultra-high dose rates required to trigger the FLASH effect harder to achieve over large areas. Importantly, the dose rate is difficult to measure directly. Time and dose linearity of a fast-resolving commercial plastic scintillation detector were characterized against an ionization chamber. The percent depth dose of a 250 MeV proton beam scanned across a small area (3.5 × 3.5 cm2) was measured at depths of 3-40 cm in solid water. The plastic scintillation detector was used to evaluate the instantaneous and voxel-averaged dose rates as a function of depth for conventional (2 nA nozzle current) and ultra-high dose rate (100 nA) beams. The response of the plastic scintillation detector was shown to be linear with time (±2.5 ms) and absorbed dose (±2%). The scintillator and ionization chamber measurements agreed well as a function of depth (and therefore energy) within 2% for depths <34 cm. Beyond 34 cm, expected quenching effects were observed in the plastic scintillation detector. The voxel-averaged dose rate varied from 52.7 Gy/s at the entrance to 29.3 Gy/s at mid-depth, to 70.4 Gy/s near the Bragg peak, while the maximum instantaneous dose rate decreased from 472 Gy/s near the entrance to 236 Gy/s at the Bragg peak. The plastic scintillation detector has proven useful for investigators to evaluate the complex relationship between dose rate and pencil-beam scanning ultra-high dose rate beam characteristics. There is a loss of dose rate near the Bragg peak due to spot widening, which may acutely impact our ability to exploit the FLASH effect for sparing normal tissues upstream of the intended treatment area. A thorough preclinical investigation of whether the FLASH effect is maintained near the Bragg peak is necessary before this technique can begin translation to the clinic.

Read full abstract
Just Published Icon Just Published
Persistent Postirradiation Skeletal Muscle Protein and Insulin Sensitivity Changes in Nonhuman Primates.

Increased incidence of diabetes has been reported after whole-body irradiation in cancer survivors and in the years after exposure in research studies of nonhuman primates. Type 2 diabetes presents in the absence of obesity and suggests that skeletal muscle, the predominant organ responsible for minute-to-minute glucose disposal, is persistently dysfunctional. We evaluated skeletal muscle (SkM) from control (CTL, n = 8) and irradiated (IRRAD, n = 16) male rhesus macaques (Macaca mulatta) that had been exposed to an average whole-body dose of 6.5 Gy after an average of 4 years of follow-up. Irradiated animals had deficient SkM basal and insulin-stimulated receptor activation that was unrelated to histologically assessed fiber size, extracellular matrix and endothelial components. Protein extracted from irradiated muscle showed that Akt2, downstream of insulin receptor activation, was sulfenyl-modified and thus a target for radiation-related glycemic dysregulation. Shotgun proteomics identified upregulation of many mitochondrial and peroxisome-associated proteins, and increases were confirmed by immunoblotting of select protein targets. Proteomic pathway enrichment mapping showed distinct protein clustering between CTL and IRRAD groups. Mitochondrial proteins were surveyed and confirm that mitochondrial turnover may be increased after irradiation with higher fission and fusion markers. The results indicate that irradiated muscle is persistently insulin resistant, with evidence of intracellular protein oxidation and shifts in mitochondrial dynamics and function.

Read full abstract
Just Published Icon Just Published
The Long-term Effects of Acute Total-Body Irradiation on Pre-irradiation Measles-vaccine-induced Immunological Memory.

Acute total-body irradiation (TBI) leads to transient dose-dependent lymphopenia. While lymphocyte numbers gradually recover, there remain subtle but long-lasting changes to B and T cell populations years after radiation exposure. The degree to which immunological memory is retained after TBI is unknown; however, it is conceivable that vaccine-induced protective immunity is jeopardized. To test this hypothesis, samples were collected from a cohort of rhesus macaques that were vaccinated against measles virus, irradiated, and then allowed to recover from the acute radiation effects for at least a year. Animals received 0 to 7.5 Gy TBI or 10 Gy with 5% bone marrow shielding. Plasma from 109 animals were evaluated for measles-binding antibodies and the ability to neutralize live measles virus. Females exhibited higher measles binding and neutralizing titers, and irradiated animals of both sexes exhibited significant radiation-dose dependent reductions in measles binding IgG and neutralizing titers. Peripheral blood mononuclear cells (PBMC) from the vaccinated, irradiated animals were then stimulated in vitro with measles antigens to evaluate cellular responses. No radiation-dose effects on CD8 T cell responses to measles antigens were detected. In contrast, PBMC from vaccinated, irradiated males exhibited radiation dose-dependent reductions in the percentages of CD4 T cells expressing activation-associated markers and cytokines in response to measles antigens. There were also significant dose- or dose/sex-interacting effects on the levels of IP10, MIP1β, and IL-6 present in the antigen-stimulated PBMC cultures. Cells from animals receiving 10 Gy with 5% bone marrow shielding exhibited signs of T-cell anergy. PBMC from females exhibited only weak responses to measles antigen stimulation regardless of radiation exposure. Collectively, these in vitro studies indicate that radiation can cause protracted dose- and sex-dependent damage to established humoral and cellular immunological memories of measles.

Read full abstract
Just Published Icon Just Published
Systematic Study of Silicon Carbide Detectors and Beam Current Transformer Signals for UHDR Single Electron Pulse Monitoring.

The use of ultra-high dose rate beams (UHDR) (> 40 Gy/s) for radiotherapy, despite its advantage of exhibiting the FLASH effect that improves the sparing of healthy tissues, faces challenges in dosimetry and beam monitoring since standard dosimeters like the ionization chamber experience saturation effects at such high dose rates. Silicon carbide (SiC) detectors have recently been demonstrated to be dose-rate independent with low-energy pulsed electron beams up to an instantaneous dose rate of 5.5 MGy/s, and has emerged as a reliable alternative technology for dosimetry in FLASH-RT. This study explored the suitability of using the SiC detector for measuring intra-pulse instantaneous dose rates, which are necessary for monitoring fluctuations within the pulse of UHDR pulsed electron beams. The experiments reported were conducted using UHDR electron beams accelerated at 9 MeV by an ElectronFlash linac and using varying different beam parameters, such as the beam current (i.e., different dose per pulse) and pulse width settings. The temporal single pulse shape signals were measured with a 10 µm thick, 4.5 mm2 area SiC detector for different configurations and compared with a well-characterized AC current transformer (ACCT) (which served as the standard monitoring system of the accelerator), and with a second ACCT placed at the same location as the SiC detector (i.e., after the applicator at the irradiation point). The results show a high level of agreement between the signals of the SiC detector and ACCT placed after the applicator at around the irradiation point. This underscores the potential of the SiC detector and the ACCT to be used for monitoring instantaneous dose rates within a pulse. Furthermore, since use of the SiC detector and ACCT are based on different physical principles, they can provide complementary beam information. A combination of the two has the potential to provide insight about a variety of variables of interest for UHDR beams. However, some discrepancies were observed when comparing the SiC signals with the ACCT installed in the LINAC, which increased linearly with decreasing dose per pulse. Further studies are required to better understand these observations.

Read full abstract
Just Published Icon Just Published
Occupational Exposure to Low Dose Ionizing Radiation and the Incidence of Surgically Removed Cataracts and Glaucoma in a Cohort of Ontario Nuclear Power Plant Workers.

Ionizing radiation is a human carcinogen and has been shown to increase the risk of non-cancerous ocular disorders. Specifically, findings from epidemiological studies suggest that ionizing radiation leads to the development of cataracts and to a lesser extent glaucoma, however, there are uncertainties of these risks at lower exposures. We analyzed data from a cohort of 60,874 Ontario Nuclear Power Plant (NPP) workers within the Canadian National Dose Registry (NDR). These workers were monitored for whole-body exposure to ionizing radiation using dosimeters, with exposure estimates derived for each year of employment. Incident cases of surgically removed cataracts and glaucoma were identified through the record linkage of occupational histories to administrative health data for Ontario between 1991 and 2022. We compared the incidence of surgically removed cataracts and glaucoma in the cohort to Ontario's general population using indirect age- and sex-standardization with matching by place of residence. We evaluated exposure-response relationships with internal cohort comparisons using age-, sex-, and calendar-period-adjusted Poisson regression. The relative risks of cataract and glaucoma were estimated across categorical measures of whole-body dose [Hp(10)] from exposure to radiation (lagged 5 years). In total, 32,855 of the 60,874 workers (58%) had a positive cumulative dose exceeding the minimum reportable threshold. Among these workers, the mean cumulative whole-body lifetime dose at end of follow-up was 23.7 mSv (interquartile range: 1.1-26.4 mSv, maximum = 959.3 mSv). Overall, 4,401 (7.2%) of workers developed glaucoma, while 2,939 (4.8%) underwent cataract-removal surgery. There was no evidence of a dose-response relationship between cumulative whole-body dose ionizing radiation (lagged 5 years) and glaucoma, but some for surgically removed cataract. Specifically, among workers with a cumulative exposure of greater than 50 mSv relative to those with an exposure of less than 0.25 mSv, the relative risks of incident glaucoma and cataract removal surgery were 0.91 (95% CI: 0.81-1.05) and 1.13 (95% CI: 0.97-1.33), respectively. The linear excess risks per 100 mSv (lagged 5 years) for cataract removal surgery was 0.055 (95% CI: -0.042 to 0.163). Our findings provide some evidence that ionizing radiation increases the risk of cataracts but not glaucoma in an occupational cohort whose lifetime cumulative dose rarely exceeded 30 mSv.

Read full abstract
Just Published Icon Just Published
Timosaponin AIII Enhances Radiosensitivity in Breast Cancer through Induction of ROS-Mediated DNA Damage and Apoptosis.

Breast cancer is a commonly diagnosed cancer, while resistance to radiation therapy remains an important factor hindering the treatment of patients. Timosaponin AIII (Tim AIII) is a steroidal saponin from the Anemarrhena asphodeloides. Its pharmacologic effects and mechanisms for enhancing radiotherapy remain largely unknown. This study investigates Tim AIII ç and aims to unravel the underlying mechanisms. Experiments, including cell cloning, scratch assays, cell cycle, apoptosis assays, immunofluorescence staining, and reactive oxygen species (ROS) assessments, were conducted on breast cancer cell lines MDA-MB-231 and JIMT-1 to investigate the impact of Tim AIII combined with radiation. Western blot analyses were used to detect γ-H2AX expression, ROS-related pathways, ATM-CHK2, and AKT-MTOR pathways. Subcutaneous tumor experiments in nude mice confirmed invivo radiation sensitization. When combined with radiation, Tim AIII significantly inhibited cell clone formation, impeded cancer cell migration, increased G2/M phase arrest and apoptosis. Immunofluorescence showed prolonged γ-H2AX signals. Molecular investigations indicated Tim AIII amplified radiation-induced ROS production, inducing ROS-mediated DNA damage and apoptosis. It activated ATM-CHK2 while inhibiting the AKT-MTOR pathway. Tim AIII enhances radiation sensitivity in breast cancer cells, both in vitro and invivo. Through ROS-mediated DNA damage and apoptosis, activation of ATM/Chk2 and inhibition of the AKT-MTOR pathway induce G2/M phase arrest, ultimately boosting radiation sensitivity via the mitochondrial-mediated apoptotic pathway.

Read full abstract
Effects of Whole-Body Carbon-Ion Beam Irradiation on Bone Marrow Death in Mice and an Examination of Candidates for Protectors or Mitigators against Carbon-Ion-Beam-Induced Bone Marrow Death.

The present study examined the effects of whole-body carbon-ion-beam irradiation on bone marrow death in mice and investigated whether compounds/materials, which were identified as efficient radio-protectors or mitigators against X-ray-radiation-induced bone marrow death, were also effective against the carbon-ion-beam-induced death of mice. Amifostine and cysteamine were used as radio-protectors and zinc-containing heat-killed yeast (Zn-yeast) and γ-tocopherol-N,N-dimethylglycine ester (γTDMG) as radio-mitigators. Amifostine or cysteamine was intraperitoneally administered in a single injection of 1.95 mmol/kg body weight 30 min before whole-body carbon-ion-beam irradiation. Zn-yeast or γTDMG was administered in a single intraperitoneal injection of 100 mg/kg body weight immediately after whole-body carbon-ion-beam irradiation. The absorbed dose dependence of the 30-day survival rate after carbon-ion-beam irradiation was analyzed. The biological effectiveness of carbon-ion-beam irradiation (LD50/30 = 5.54 Gy) was estimated as 1.2 relative to X-ray irradiation (LD50/30 = 6.62 Gy). The dose reduction factors (DRF) of amifostine, cysteamine, Zn-yeast, and γTDMG estimated for carbon-ion-beam irradiation were 1.75, 1.53, 1.16, and 1.15, respectively. Radio-protectors and -mitigators that were effective against photon irradiation also exhibited efficacy against carbon-ion-beam irradiation; however, the DRF for carbon-ion-beam irradiation was slightly smaller than that for photon irradiation. Based on the radio-protective effects of amifostine and cysteamine, the contribution of ROS/free radicals to carbon-ion-beam-induced bone marrow death was 70-90% to that of photon irradiation. Since the suppression of tumor growth by carbon-ion-beam irradiation was not inhibited by the treatment with γTDMG or Zn-yeast, both mitigators have potential as normal tissue-selective protectors in carbon-ion irradiation.

Read full abstract