328 publications found
Sort by
Liver Extracellular Matrix-Based Nanofiber Scaffolds for the Culture of Primary Hepatocytes and Drug Screening.

Immortalized liver cell lines and primary hepatocytes are currently used as in vitro models for hepatotoxic drug screening. However, a decline in the viability and functionality of hepatocytes with time is an important limitation of these culture models. Advancements in tissue engineering techniques have allowed us to overcome this challenge by designing suitable scaffolds for maintaining viable and functional primary hepatocytes for a longer period of time in culture. In the current study, we fabricated liver-specific nanofiber scaffolds with polylactic acid (PLA) along with a decellularized liver extracellular matrix (LEM) by the electrospinning technique. The fabricated hybrid PLA-LEM scaffolds were more hydrophilic and had better swelling properties than the PLA scaffolds. The hybrid scaffolds had a pore size of 38 ± 8 μm and supported primary rat hepatocyte cultures for 10 days. Increased viability (2-fold increase in the number of live cells) and functionality (5-fold increase in albumin secretion) were observed in primary hepatocytes cultured on the PLA-LEM scaffolds as compared to those on conventional collagen-coated plates on day 10 of culture. A significant increase in CYP1A2 enzyme activity was observed in hepatocytes cultured on PLA-LEM hybrid scaffolds in comparison to those on collagen upon induction with phenobarbital. Drugs like acetaminophen and rifampicin showed the highest toxicity in hepatocytes cultured on hybrid scaffolds. Also, the lethal dose of these drugs in rodents was accurately predicted as 1.6 g/kg and 594 mg/kg, respectively, from the corresponding IC50 values obtained from drug-treated hepatocytes on hybrid scaffolds. Thus, the fabricated liver-specific electrospun scaffolds maintained primary hepatocyte viability and functionality for an extended period in culture and served as an effective ex vivo drug screening platform to predict an accurate in vivo drug-induced hepatotoxicity.

Relevant
Boron Nitride's Morphological Role in the Design of Injectable Hyaluronic Acid Based Hybrid Artificial Synovial Fluid.

The treatment process of osteoarthritis (OA) is challenging as it affects not only cartilage but also subchondral bone, ligament attachment capsules, synovium, and surrounding muscle tissue. Therefore, the search for preventive treatment or methods to slow the onset of the condition. Hexagonal boron nitride (hBN) has a graphite-like lamellar structure and is thought to facilitate cartilage movement for biomedical applications, just like in bearing systems. Hyaluronic acid (HA) is one of the natural polymers that can be used to transport boron nitride and maintain its presence in joints for a long time. In this study, hybrid hydrogels were formulated by using boron nitride nanoparticles and nanosheets. The rheological properties of the hydrogels were evaluated according to the structural differences of hBN. Characterizations have shown that hybrid hydrogels can be produced in injectable form, and the rheological properties are strongly related to the structural properties of the added particle. It has been determined that hBN added to the hydrogel structure reduces the dynamic viscosity of the zero-shear point and the deformation rate of the hydrogel and also changes the viscoelastic properties of the hydrogel depending on boron nitride's structural differences. The suggested mechanism is the hybrid hydrogel that exhibits lower viscosity as the layers detach from each other or disperses the agglomerates under applied shear stress. hBN, which has been proposed as a new strategy for joint injections, is thought to be a promising candidate for the treatment of OA due to its lamellar structures.

Relevant
Rapid Surface Modification of Stainless Steel 304L Electrodes for Microbial Electrochemical Sensor Application.

Electrogenic microorganisms serve as important biocatalysts for microbial electrochemical sensors (MESes). The electrical signal produced is based on the rate of electron transfer between the microbes and electrodes, which represents the biotoxicity of water. However, existing MESes require complex and sophisticated fabrication methods. Here, several low-cost and rapid surface modification strategies (carbon powder-coated, flame-oxidized, and acid-bleached) have been demonstrated and studied for biosensing purposes. Surface-modified MESe bioanodes were successfully applied to detect multiple model pollutants including sodium acetate, ethanol, thinner, and palm oil mill effluent under three different testing sequences, namely, pollutant incremental, pollutant dumping, and water dilution tests. The carbon powder-coated bioanode showed the most responsive signal profile for all the three tests, which is in line with the average roughness values (Ra) when tested with atomic force microscopy. The carbon powder-coated electrode possessed a Ra value of 0.844, while flame-oxidized, acid-bleached, and control samples recorded 0.323, 0.336, and 0.264, respectively. The higher roughness was caused by the carbon coating and provided adhesive sites for microbial attachment and growth. The accuracy of MESe was also verified by correlating with chemical oxygen demand (COD) results. Similar to the sensitivity test, the carbon powder-coated bioanode obtained the highest R2 value of 0.9754 when correlated with COD results, indicating a high potential of replacing conventional water quality analysis methods. The reported work is of great significance to showcase facile surface modification techniques for MESes, which are cost-effective and sustainable while retaining the biocompatibility toward the microbial community with carbon-based coatings.

Relevant
One Step Encapsulation of Mesenchymal Stromal Cells in PEG Norbornene Microgels for Therapeutic Actions.

Cell therapies require control over the cellular response under standardized conditions to ensure continuous delivery of therapeutic agents. Cell encapsulation in biomaterials can be particularly effective at providing cells with a uniformly supportive and permissive cell microenvironment. In this study, two microfluidic droplet device designs were used to successfully encapsulate equine mesenchymal stromal cells (MSCs) into photopolymerized polyethylene glycol norbornene (PEGNB) microscale (∼100-200 μm) hydrogel particles (microgels) in a single on-chip step. To overcome the slow cross-linking kinetics of thiol-ene reactions, long dithiol linkers were used in combination with a polymerization chamber customized to achieve precise retention time for microgels while maintaining cytocompatibility. Thus, homogeneous cell-laden microgels could be continuously fabricated in a high-throughput fashion. Varying linker length mediated both the gel formation rate and material physical properties (stiffness, mass transport, and mesh size) of fabricated microgels. Postencapsulation cell viability and therapeutic indicators of MSCs were evaluated over 14 days, during which the viability remained at least 90%. Gene expression of selected cytokines was not adversely affected by microencapsulation compared to monolayer MSCs. Notably, PEGNB-3.5k microgels rendered significant elevation in FGF-2 and TGF-β on the transcription level, and conditioned media collected from these cultures showed robust promotion in the migration and proliferation of fibroblasts. Collectively, standardized MSC on-chip encapsulation will lead to informed and precise translation to clinical studies, ultimately advancing a variety of tissue engineering and regenerative medicine practices.

Relevant
Molecular Dynamics for the Optimal Design of Functionalized Nanodevices to Target Folate Receptors on Tumor Cells.

Atomistic details on the mechanism of targeting activity by biomedical nanodevices of specific receptors are still scarce in the literature, where mostly ligand/receptor pairs are modeled. Here, we use atomistic molecular dynamics (MD) simulations, free energy calculations, and machine learning approaches on the case study of spherical TiO2 nanoparticles (NPs) functionalized with folic acid (FA) as the targeting ligand of the folate receptor (FR). We consider different FA densities on the surface and different anchoring approaches, i.e., direct covalent bonding of FA γ-carboxylate or through polyethylene glycol spacers. By molecular docking, we first identify the lowest energy conformation of one FA inside the FR binding pocket from the X-ray crystal structure, which becomes the starting point of classical MD simulations in a realistic physiological environment. We estimate the binding free energy to be compared with the existing experimental data. Then, we increase complexity and go from the isolated FA to a nanosystem decorated with several FAs. Within the simulation time framework, we confirm the stability of the ligand-receptor interaction, even in the presence of the NP (with or without a spacer), and no significant modification of the protein secondary structure is observed. Our study highlights the crucial role played by the spacer, FA protonation state, and density, which are parameters that can be controlled during the nanodevice preparation step.

Open Access
Relevant
Atomic-Level Insights into Hollow Silica-Based Materials for Drug Delivery: Effects of Wettability and Porosity.

Experimental evidence has demonstrated that the drug carrier capacity can be significantly enhanced through the use of hollow silica particles. Nevertheless, the effects of varying functional drug carrier surfaces and porous structures remain ambiguous. This study employs molecular dynamics simulations to examine the effects of varying the surface wettability, pore size, and flow velocity on the transfer process. The different levels of wettability of the silica surface with the coarse-grained water model is illustrated by adjusted interaction parameters. The effect of wettability is investigated. With weak interactions, the flow molecules form a nanodroplet to transfer through the porous structure. A strong interaction will lead to molecules flowing as a liquid film to transfer through the structure. Interestingly, the "contradiction effect" is observed when the flow molecules fail to penetrate the porous structure with weak interactions, during which surface tension dominates their flow behavior. Moreover, different porous structures are considered. The flow behaviors are divided into three processes: (1) fast flowing, (2) transient point, and (3) penetration flowing. Furthermore, the concept of surface molecules is defined to quantitatively measure the effect of porosity. A recommended contact angle is proposed. The results will pave the way for more carrier structures in medical engineering.

Relevant
Automatic Photo-Cross-Linking System for Robotic-Based In Situ Bioprinting.

This work reports the design and validation of an innovative automatic photo-cross-linking device for robotic-based in situ bioprinting. Photo-cross-linking is the most promising polymerization technique when considering biomaterial deposition directly inside a physiological environment, typical of the in situ bioprinting approach. The photo-cross-linking device was designed for the IMAGObot platform, a 5-degree-of-freedom robot re-engineered for in situ bioprinting applications. The system consists of a syringe pump extrusion module equipped with eight light-emitting diodes (LEDs) with a 405 nm wavelength. The hardware and software of the robot were purposely designed to manage the LEDs switching on and off during printing. To minimize the light exposure of the needle, thus avoiding its clogging, only the LEDs opposite the printing direction are switched on to irradiate the newly deposited filament. Moreover, the LED system can be adjusted in height to modulate substrate exposure. Different scaffolds were bioprinted using a GelMA-based hydrogel, varying the printing speed and light distance from the bed, and were characterized in terms of swelling and mechanical properties, proving the robustness of the photo-cross-linking system in various configurations. The system was finally validated onto anthropomorphic phantoms (i.e., a human humerus head and a human hand with defects) featuring complex nonplanar surfaces. The designed system was successfully used to fill these anatomical defects, thus resulting in a promising solution for in situ bioprinting applications.

Open Access
Relevant
On-Site Construction of a Full-Thickness Skin Equivalent with Endothelial Tube Networks via Multilayer Electrospinning for Wound Coverage.

Novel full-thickness skin substitutes are of increasing interest due to the inherent limitations of current models lacking capillary networks. Herein, we developed a novel full-thickness skin tissue containing blood capillary networks through a layer-by-layer assembly approach using a handy electrospinning apparatus and evaluated its skin wound coverage potential in vivo. The average diameter and thickness of fabricated poly-ε-caprolactone-cellulose acetate scaffolds were easily tuned in the range of 474 ± 77-758 ± 113 nm and 9.43 ± 2.23-29.96 ± 5.78 μm by varying electrospinning distance and duration, as indicated by FE-SEM. Besides, keratinocytes exhibited homogeneous differentiation throughout the fibrous matrix prepared with electrospinning distance and duration of 9 cm and 1.5 min within five-layer (5L) epidermal tissues with thickness of 135-150 μm. Moreover, coculture of vascular endothelial cells, circulating fibrocytes, and fibroblasts within the 5L dermis displayed network formation in vitro, resulting in reduced inflammatory factor levels and enhanced integration with the host vasculature in vivo. Additionally, the skin equivalent grafts consisting of the epidermal layer, biomimetic basement membrane, and vascularized dermis layer with an elastic modulus of approximately 11.82 MPa exhibited accelerated wound closure effect indicative of re-epithelialization and neovascularization with long-term cell survival into the host, which was confirmed by wound-healing rate, bioluminescence imaging activity, and histological analysis. It is the first report of a full-thickness skin equivalent constructed using a battery-operated electrospinning apparatus, highlighting its tremendous potential in regenerative medicine.

Relevant