Abstract

A series of 458 consecutive ultrasound-guided biopsies in 347 patients - 171 fine-needle aspiration biopsies (FNABs) and 287 1.2-mm needle core biopsies (NCBs) - was analysed for diagnostic yield and complications. FNAB was diagnostic in 107 (64%) biopsies of focal lesions with a correct diagnosis of malignancy in 86 of 125 biopsies (69%) and of benign disease in 21 of 43 (49%) biopsies. NCB provided a correct diagnosis in 189 (90%) biopsies for focal lesions, divided into 140 of 159 (88%) correct for malignancy and 49 of 50 (98%) correct for benign disease. In 69 patients examined with both FNAB and NCB on the same occasion, 50 out of 55 malignant lesions were identified with NCB but only 34 with FNAB; all 14 benign lesions were correctly identified by NCB, and only 6 by FNAB. Clinical relevant bleeding complications occurred in 6 out of 458 biopsies (1.3%) - 3 out of 287 following NCB (1.0%) and 3 out of 171 following FNAB (1.8%). It is concluded that if FNAB is replaced with 1.2-mm NCB using an automat...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.