Abstract

Stent-assisted coiling with two stents has been described in some series for the treatment of complex and wide-neck bifurcation aneurysms. Our aim was to report our experience of a stent-assisted coiling technique with double stents in "Y" and "X" configurations, with emphasis on safety, feasibility, and efficacy. Clinical and angiographic outcomes of patients for whom the strategic therapeutic option was the stent-assisted coiling technique in a Y or X configuration for neck scaffolding from June 2006 to June 2013 were retrospectively analyzed. One hundred five aneurysms in 97 patients were treated during 100 consecutive procedures. There were 54.2% (57/105) MCA, 28.6% (30/105) anterior communicating artery, 16.2% (17/105) basilar tip, and 1.0% (1/105) ICA termination aneurysms. A Y stent placement was used to treat 87 aneurysms in 85 procedures; an X stent placement was used to treat 7 aneurysms in 6 procedures, while 9 procedures failed for 11 aneurysms. There were 10.0% (10/100) procedure-related permanent neurologic deficits and 1.0% (1/100) death. The immediate angiographic controls showed a complete occlusion in 47.6% (50/105) of the aneurysms and a partial (neck or sac remnant) occlusion in 52.4% (55/105). To date, 81.0% (85/105) of the aneurysms have been followed up (mean, 17 months) with angiography, disclosing a recanalization in 5.9% (5/85) and an improvement in 42.4% (36/85). At discharge and follow-up, the mRS score was 0 in 83.5% (81/97) of patients, 1 in 4.1% (4/97), 2 in 3.1% (3/97), 3 in 4.1% (4/97), 4 in 3.1% (3/97), and 6 in 2.1% (2/97). Y and X stent-assisted coiling of complex and wide-neck intracranial bifurcation aneurysms is an effective technique.

Highlights

  • BACKGROUND AND PURPOSEStent-assisted coiling with two stents has been described in some series for the treatment of complex and wide-neck bifurcation aneurysms

  • Endovascular treatment of intracranial aneurysms became a valid alternative to neurosurgery[1] and is performed as a first option in many centers

  • Several concerns remain regarding stent combinations and the rate of neurologic complications, in our institution since 2006, we have been using this technique with different stent combinations to treat complex and wide-neck bifurcation intracranial aneurysms

Read more

Summary

Objectives

Our aim was to report our experience of a stent-assisted coiling technique with double stents in “Y” and “X” configurations, with emphasis on safety, feasibility, and efficacy

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.