Abstract

A 2-month-old female (3.4 kg, 50 cm) with Down syndrome and left-to-right shunting congenital heart defects underwent an unsuccessful transcatheter ductal closure, followed by bilateral implantation of manually modified microvascular plugs (MVP-9Q) from Medtronic (Minneapolis, MN, USA), used as pulmonary flow restrictors. Post-procedure, she developed febrile respiratory distress, leading to admission to the intensive care unit. Despite initial improvement, she was readmitted with respiratory syncytial virus infection, progressing to bilateral pneumonic consolidation. Subsequent complications included pulmonary artery aneurysmal dilatation attributed to pulmonary flow restrictors, which necessitated urgent surgery two months after their implantation. The surgery involved removing the pulmonary flow restrictors and repairing the injuries to the pulmonary artery, followed by management with extracorporeal support and targeted antibiotics. The patient recovered over 12 months.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.