Abstract

Monolithic construction in winter faces problems of concrete strength set at negative ambient temperature. In order to ensure the necessary temperature conditions for hardening concrete use different methods of heating structures. One of the most effective ways is to warm up using a heating wire. The tasks of stood concrete in winter conditions are multifactorial, and computer modeling can significantly improve the efficiency of work. The ELCUT software complex is a tool in solving such problems, based on the method of the final elements. On the example of a monolithic foundation slab, the process of hardening of concrete at the temperature of the coldest five-day and medium-winter in Bratsk was simulated. The calculation of the concrete strength set and the analysis of temperature fields, taking into account the requirements for crack resistance, has been made. Computer simulations allowed to pick up the parameters of laying the heating wire in the concrete.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.