Abstract

A series of pressure tests were conducted to systematically investigate the wind loads on isolated solar panels mounted on the rooftops of tall buildings. The effects of panel location, tilt angle (β = 15°, 30°, and 45°), and building height (H = 24, 48, 72, and 96 m) were examined. Peak loads from taps were found two times as large as that from modules and panels. An increase in H induced a decrease in the largest mean and negative peak net panel force coefficients, which is attributed to the enhanced two-dimensionality of flows for buildings with lower heights. Specifically, the largest most critical negative peak net panel force coefficients at H = 24 m were approximately 20% larger than those at H = 96 m. Attention should be paid to wind loads on roof-mounted solar panels attached to buildings with lower heights. Besides, buildings with lower heights tend to cause more significant fluctuations of wind pressure on solar panels. Moreover, rooftop solar panels on buildings with lower heights are likely to have positive mean panel force coefficients due to the flow reattachment over roofs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.