Abstract

This paper presents data for convective heat transfer coefficients on the front surface of a free-standing array of solar collectors mounted on the flat roof of a low warehouse-type building and exposed to the wind. The data were obtained by testing a 1:36 scale model in highly turbulent nonuniform flows which simulated the natural wind. For typical full scale conditions, the heat transfer coefficients are substantially lower than those given by a commonly used correlation. The coefficients are only mildly sensitive to wind direction, location of the array on the roof and characteristics of the wind.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.