Abstract

In various electronic and electrical devices for communication systems, impedance transformers with wide bandwidths are important. In this article, Chebyshev impedance transformers for ohmic loads with order 3 are presented at different frequencies and load impedance values using Duroid and FR4 substrates (εr = 2.2 and εr = 4.4 respectively). Simulated results are shown using the software Advanced Design System (ADS). The thickness of the substrate for FR4 dielectric material is 1.544 mm and for Duroid material is 1.27mm. The matching transformers were performed at 1 GHz, 1.5 GHz, 2 GHz, and 1.5 GHz for two load impedance 100 Ohms and 75 Ohms from 50 Ohms showing a reflection coefficient Γm = 0.05. The S11 scattering parameter was obtained.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.