Abstract

The specific absorption rate (SAR) measurement procedure for radio base station antennas using flat phantoms has been investigated and standardized by the International Electrotechnical Commission (IEC). This paper discusses the effectiveness of this procedure for considering Japanese human models based on numerical simulations with validation of whole-body average SAR (WBSAR) measurement. The WBSAR in two Japanese anatomical human models (adult male and 3-year-old child) and two box-shaped phantoms (large and small) using a standardized SAR measurement procedure are compared at 788 MHz and 3.5 GHz. Computational results show that the SAR measurement procedure in the IEC leads to overestimated WBSAR compared to those in Japanese anatomical human models. These results imply that the SAR measurement procedure above is applicable to not only some commonly used but Japanese human models. The WBSAR obtained using SAR estimation formulae in the IEC is also overestimated compared to those in Japanese anatomical human models. In addition, to reduce the measurement time and simplify the post-processing, this paper introduces a SAR measurement procedure based on the two-dimensional SAR distribution around the surface of the bottom of the phantom and the one-dimensional exponential decay of the SAR distribution in the direction of the phantom depth. SAR measurement examples of antennas for small radio base stations are also presented.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.