Abstract

The issue of thermal breakthrough is often encountered in the extraction of geothermal fluids with reinjection. This study analyzes the minimum safe distance between doublet wells that will maintain thermal productivity under various conditions at the Huangtsuishan geothermal site. A conceptual model is constructed and hypothetical exploitation scenarios are explored. The results show that a distance of 300 m is required to avoid a thermal break in 80 years with 120 tons/hour pumped and 90 % reinjected at the Huangtsuishan Geothermal site. A regression formula was provided as a guideline for the minimum required doublet distance for various pumping rates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.