Abstract
Ceramic composites have performed very well under adverse edge loading conditions when used in like‐on‐like configurations, where the femoral head and acetabular cup are of the same material. The aim of this study was to determine the wear of pure alumina (Al2O3), alumina toughened zirconia (ATZ) and zirconia toughened alumina (ZTA) when used in mixed bearing combinations, under edge loading conditions due to translational mal‐positioning. The head‐on‐cup configurations of three ceramic materials were ATZ‐on‐ZTA, ZTA‐on‐ATZ, Al2O3‐on‐ATZ, ATZ‐on‐Al2O3, Al2O3‐on‐ZTA, and ZTA‐on‐Al2O3. They were tested on the Leeds II hip simulator under microseparation conditions. The bedding in and steady state wear rates of ATZ‐on‐ZTA were 1.16mm3/million cycles and 0.18mm3/million, respectively, and for ATZ‐on‐Al2O3 were 0.66 mm3/million cycles and 0.20 mm3/million, respectively. The wear rates of the other bearing combinations under these adverse microseparation conditions, Al2O3‐on‐ATZ, Al2O3‐on‐ZTA, ZTA‐on‐ATZ and ZTA‐on‐Al2O3 were very low with no clear bedding in and steady state phases, and with steady state wear rates lower than 0.11 mm3/million. The mixed material combinations tested in this study have shown slightly higher wear rates when compared to ATZ in like‐on‐like configuration reported previously, but superior wear resistance when compared to alumina‐on‐alumina bearings tested previously under the same adverse microseparation conditions. © 2016 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1361–1368, 2017.
Highlights
The wear of ceramic-on-ceramic materials in vitro under standard hip simulator conditions is very low[1,2] (
Microseparation was achieved by lateralising the head relative to the acetabular cup by 0.4–0.5 mm during swing phase and edge loading occurred at heel strike (Figure 1)
For comparison, the wear rates of all combinations were split into bedding in phase between 0 and 1 million cycles and steady state phase between 1 and 4 million cycles
Summary
The wear of ceramic-on-ceramic materials in vitro under standard hip simulator conditions is very low[1,2] (
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Biomedical Materials Research Part B: Applied Biomaterials
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.