Abstract
This paper presents an analytical investigation of water hammer pressure variation in a reservoir-pipe-valve system. Laplace transform method is used to get the analytical solutions for different characteristics of the valve closing. Specifically, sudden valve closing and piecewise linear closing are used, the latter can be treated as approximated arbitrary characteristics of valve closing. Unsteady wall friction is also included. The new solutions compare well with the previous experimental data. The results show that this solution is suitable for water hammer with laminar and low Reynolds number turbulent unsteady flow. The effects of different characteristics of the valve closing on the water hammer pressure variations are also studied. This solution can be a better choice for optimization of valve closing to reduce the maximum water hammer pressure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.