Abstract

Exposure to sevoflurane (SEV) and nitrous oxide during ventilation using a Combitube (37Fr) small adult (SA) was compared with waste gas exposure using conventional endotracheal tubes. Trace concentrations of SEV and nitrous oxide were assessed using a direct reading spectrometer during 40 gynaecological laparoscopic procedures under general anaesthesia. Measurements were made at the patients' mouth and in the anaesthetists' breathing zone. Mean (SD) concentrations of SEV and nitrous oxide measured at the patients' mouth were comparable in the Combitube SA (SEV 0.6 (0.2) p.p.m.; nitrous oxide 9.7 (8.5) p.p.m.) and endotracheal tube group (SEV 1.2 (0.8) p.p.m.; nitrous oxide 17.2 (10.6) p.p.m.). These values caused comparable contamination of the anaesthetists' breathing zone (SEV 0.6 (0.2) p.p.m. and nitrous oxide 4.3 (3.7) p.p.m. for the Combitube SA group, compared with SEV 0.5 (0.2) p.p.m. and nitrous oxide 4.1 (1.8) p.p.m. for the endotracheal tube group). We conclude that the use of the Combitube SA during positive pressure ventilation is not necessarily associated with increased waste gas exposure, especially when air conditioning and scavenging devices are available.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.