Abstract
A simple, centrifugeless vortex-assisted ionic liquid-based dispersive liquid-liquid micro-extraction method was developed for spectrofluorometric determination of Rhodamine B dye. Analytical extraction parameters including pH, type and amount of ionic liquid, salt concentration, vortex rate and time were examined and optimized. Matrix effects of potentially interfering ions and dyes were investigated and their tolerable concentrations were determined by applying optimum conditions. Detection limit and preconcentration factor were determined 0.01 μg L-1 and 30, respectively. Dynamic range of the method was linear at RhB concentration range between 0.025 and 1000 μg L-1. Relative standard deviations were 3.9% for the ten replicates measurements of 0.125 μg L-1 Rhodamine B. The method was successfully applied to different samples including anti-freezes, liquid soap, matches, red pencil core and lipsticks. RhB concentrations of liquid and solid samples were determined between 2.05 μg mL-1 and 10.05 μg mL-1 and 307 μg g-1 and 2.75 mg g-1, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Iğdır Üniversitesi Fen Bilimleri Enstitüsü Dergisi
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.