Abstract

Purpose. Evaluation of diagnostic efficiency and safety of volumetric dynamic 640-slice CT in the detection of stenotic lesions of the coronary arteries.Materials and methods. In University clinic N1 in 2016–2017 years we investigated 86 patients with ischemic heart disease or valvular heart disease. All patients were fulfilled volumetric dynamic 640-slice CT-coronarography with retrospective ECG-synchronization and subsequent multiparametric reconstruction and evaluation of the coronary vessels. We determinate the degree of stenosis of the coronary arteries. The results are compared with data of the standard coronarography. 22 patients previously had stenting coronary arteries. In 12 cases, patients have atrial fibrillation. The selection criterion for the study was the absence of progression of the disease for at least 6 weeks and a minimum period of 3 months of optimal medical therapy. The study did not include patients with acute coronary syndrome and patients with aortic-coronary bypass surgery in history. All patients were performed CT-angiography on 640-slice CT Aquilion One (Toshiba, Japan). Contrast agent (Ultravist-370) of room temperature was injected into the cubital vein via catheter 18G at a speed of 4.5 ml/s.Results. Statistical criteria in the detection of coronary artery stenosis at MSCT-coronarography were as follows: sensitivity – 94.3%, specificity – 93.5%, accuracy – 92.8%, positive prognostic value – 96.4%, negative prognostic value – 87.3%. Spearman rank correlation coefficient in the evaluation of coronary artery lesions according to these methods was 0.68.Conclusion. Volumetric dynamic 640-slice CT-angiography is a highly sensitive safe non-invasive method of examination of patients with different cardiovascular diseases, which is characterized by low radiation dose and high security.

Highlights

  • Цель исследования – оценка диагностической эффективности и безопасности объемной динамической 640-срезовой мультиспиральной компьютерной томографии в отношении выявления стенозов коронарных артерий

  • In University clinic N1 in 2016–2017 years we investigated 86 patients with ischemic heart disease or valvular heart disease

  • The results are compared with data of the standard coronarography. 22 patients previously

Read more

Summary

Materials and methods

In University clinic N1 in 2016–2017 years we investigated 86 patients with ischemic heart disease or valvular heart disease. All patients were fulfilled volumetric dynamic 640-slice CT-coronarography with retrospective ECG-synchronization and subsequent multiparametric reconstruction and evaluation of the coronary vessels. We determinate the degree of stenosis of the coronary arteries. The results are compared with data of the standard coronarography. 32 МЕДИЦИНСКАЯ ВИЗУАЛИЗАЦИЯ 2018, том 22, No4 had stenting coronary arteries. In 12 cases, patients have atrial fibrillation. The selection criterion for the study was the absence of progression of the disease for at least 6 weeks and a minimum period of 3 months of optimal medical therapy. The study did not include patients with acute coronary syndrome and patients with aortic-coronary bypass surgery in history. All patients were performed CT-angiography on 640-slice CT Aquilion One (Toshiba, Japan). Contrast agent (Ultravist-370) of room temperature was injected into the cubital vein via catheter 18G at a speed of 4.5 ml/s

Results
Conclusion
Материал и методы
Список литературы
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.