Abstract
The review analyzes the patent literature dealing with metal protection by volatile corrosion inhibitors (VCIs) and materials based thereon. It has been found inhibitors of atmospheric corrosion with vapor pressure above 10 –5 mmHg can be used as VCIs, including nitrogen-containing bases of various nature, salts of nitrogen-containing bases with some inorganic or organic acids, organic nitro compounds, esters of organic and inorganic acids, heterocyclic nitrogen-containing compounds, etc. Vapor-phase metal protection is also performed using non-volatile compounds and formulations that can release compounds of the above types upon hydrolysis. VCIs for temporary protection can be used in the form of active compounds, solutions, packaging materials, porous emitters, inhibited air, or in special forms intended for the protection of specific product types. VCIs can be used for permanent protection of metal articles within polymer coatings (paints) and working liquids (hydraulic, cooling liquids, etc.).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Corrosion and Scale Inhibition
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.