Abstract

The role of cone-beam CT (CBCT) in demonstrating anterior skull base defects (ASBDs), differing in size and location, was investigated. The study was designed to describe the potential advantage of CBCT in the setting of an intraoperative cerebrospinal fluid (CSF) leak. In all, 120 ASBD were evaluated in 5 cadaver heads. Orthogonal and oblique slices were reconstructed. Observer studies assessed the visibility of ASBD in each location as a function of defect size. For 1-, 2-, and 4-mm defects, the percentage that were undetectable ranged from 20% to 33%, 0% to 14%, and 0% to 5%, respectively. Confident breach detection increased with defect size and was most challenging in the lateral lamella and cribriform. CBCT permitted confident detection of ASBD as small as about 2 mm in the fovea ethmoidalis and planum. Oblique views were found to be superior to orthogonal planes. The ability to identify ASBD depended on the size and location of defect. Oblique viewing planes were optimal for ASBD visualization.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.