Abstract

Microfluidic devices are an emerging platform for a variety of experiments involving bacterial cell culture, and has advantages including cost and convenience. One inevitable step during bacterial cell culture is the measurement of cell concentration in the channel. The optical density measurement technique is generally used for bacterial growth estimation, but it is not applicable to microfluidic devices due to the small sample volumes in microfluidics. Alternately, cell counting or colony-forming unit methods may be applied, but these do not work in situ; nor do these methods show measurement results immediately. To this end, we present a new vision-based method to estimate the growth level of the bacteria in microfluidic channels. We use Fast Fourier transform (FFT) to detect the frequency level change of the microscopic image, focusing on the fact that the microscopic image becomes rough as the number of cells in the field of view increases, adding high frequencies to the spectrum of the image. Two types of microfluidic devices are used to culture bacteria in liquid and agar gel medium, and time-lapsed images are captured. The images obtained are analyzed using FFT, resulting in an increase in high-frequency noise proportional to the time passed. Furthermore, we apply the developed method in the microfluidic antibiotics susceptibility test by recognizing the regional concentration change of the bacteria that are cultured in the antibiotics gradient. Finally, a deep learning-based data regression is performed on the data obtained by the proposed vision-based method for robust reporting of data.

Highlights

  • Measurement of bacterial cell number is a critical process during bacterial cell culture for clinical diagnosis as well as the antibiotic susceptibility test (AST) [1,2,3]

  • The data shows a constant increase in bacterial growth as time passes, showing that the proposed method can estimate the change of the bacteria in the microfluidic channels regardless of the presence of the agar medium

  • This paper proposed and demonstrated the vision-based method for estimating the bacterial growth level in microfluidic channels, where measurements using the conventional methods are

Read more

Summary

Introduction

Measurement of bacterial cell number is a critical process during bacterial cell culture for clinical diagnosis as well as the antibiotic susceptibility test (AST) [1,2,3]. The OD method is limited in usage with microfluidic platforms, as most commercial OD measurement devices are not designed to detect the absorbance level of small volumes of culture broth (

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.