Abstract
The occurrence of matrix cracks, fibre failures and delaminations results in a critical degradation of the structural integrity of composites. A reliable early detection of these damages is mandatory for a safe operation. In this paper, the application of Vibro-Acoustic Modulation measurement in notched carbon fibre reinforced polymers (CFRP) for damage detection is demonstrated. A piezoceramic actuator introduces an ultrasonic signal into the specimen, which is modulated by a low-frequency vibration excited by a servo-hydraulic testing system. The specimens tested are open hole tensile specimens according to ASTM D5766, made from a quasi-isotropic CFRP layup. Degradation in the form of matrix cracks or delaminations localised along the drill hole significantly reduces the stiffness and can be detected as a modulation increase. Taking into account the extent of the crack size and the acoustic emission (AE), a magnitude estimate of the modulation increase is possible. In consequence, the presented method can be used for damage monitoring in CFRP.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.