Abstract

This paper is concerned with an experimental modal analysis of a loudspeaker system. Based on Frequency Response Functions (FRFs) measured in about 500 points uniformly spaced on the front panel of the loudspeaker system several vibrations modes of the loudsneaker membranes have been found. Then, the vibrations of the loudspeaker membranes were compared with vibrations of the cabinet of the loudspeaker system. It has been shown that the vibrations of the loudspeaker case were very small relative to the vibration of the loudspeaker membranes. Thus, the loudspeaker cabinet, which may be considered as a set of vibrating plates, is rather a source of a very weak sound and may be neglected. It does not influence significantly on the acoustics field radiated by the loudspeaker system.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.