Abstract

This paper presents a velocity profile measurement technique using a ultrasound time-domain correlation method (UTDC). The system is based on the cross correlation between two consecutive echoes of ultrasonic pulses to detect the velocity. The UTDC has two advantages over a conventional ultrasound pulse Doppler method. First, the system has a higher time resolution than the pulse Doppler method. Second, the system does not have a limitation in maximum measurable velocity, which is limited by Nyquist’s sampling theorem. In this paper, the velocity profile measurement in turbulent pipe flow using the UTDC is performed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.