Abstract
In this paper, a variable perturbation size adaptive perturb and observe (P&O) maximum power point tracking (MPPT) algorithm is proposed to track the maximum power under sudden changes in irradiance. The proposed method consists of three algorithms, namely current perturbation algorithm (CPA), adaptive control algorithm (ACA), and variable perturbation algorithm (VPA). CPA always tries to operate the photovoltaic (PV) panel at maximum power point (MPP). ACA sets the operating point closer to MPP, only if the operating limits are violated. These operating limits are expressed in terms of the operating current range of the PV panel and the sudden changes in irradiance. VPA dynamically reduces the perturbation size based on polarity of change in power. Two-stage variable size perturbation is proposed in this paper. The proposed algorithm is realized using a boost converter. The effectiveness of proposed algorithm in terms of dynamic performance and improved stability is validated by detailed simulation and experimental studies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.