Abstract

A slightly modified Burnett apparatus has been used to measure 32 vapor-pressure data for HFC-32 in the temperature range from 273.39 to 347.29 K. The uncertainties of temperature and pressure are estimated to be within ±10 mK and ±500 Pa, respectively. The purity of the sample used in this work is 99.95%. On the basis of our data and of data from the literature, a vapor-pressure equation for HFC-32 is also proposed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.