Abstract

The pressure on the dew line and density of the gas-phase 69.2 wt.% R134a / 30.8wt.% R227ea refrigerant were investigated using a constant volume piezometer in the temperature range from 293 to 373 K and at pressures from 0.45 to 3.1 MPa. The speed of sound of the 70.1 wt.% R134a / 29.9 wt.% R227ea mixture (323-373 K, 1.2-1.5 MPa) was also measured using an ultrasonic interferometer. The measurement errors of the temperature, pressure, density, and speed of sound were ±20 mK, ±4 kPa, ± (0.15–0.25)%, and ± (0.2–0.3)%, respectively. Approximation dependences of the studied properties were obtained and their errors were estimated. The obtained results were compared with the calculations using the REFPROP program.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.