Abstract

Spin echo or gradient echo magnetic resonance imaging provides enough information to plan patient management and can be completed with the use of three-dimensional magnetic resonance angiography to evaluate the need for reintervention, assess follow-up, or discharge the patient. From 1990-2003, we evaluated 101 patients after initial corrective surgery for aortic coarctation at the age of 3.1 +/- 3 years, with subsequent postoperative assessment at 1 year and again 12.4 +/- 4.2 years later. No mortality was registered during the follow-up. Corrective surgery was performed in 32 patients (31.6 %) before the first month of life. All the patients were evaluated with spin-echo and echo gradient and 34 were evaluated with magnetic resonance angiography. The patients were classified into two groups: group A consisted of 68 patients (11 < 1 month old) with no complications. End-to-end anastomosis was performed in 55, the Alvarez technique in five, the Waldhausen technique in six, and conduit in two. Group B consisted of 33 patients complicated with early aortic recoarctation (21 corrected before the age of 1 month). End-to-end anastomosis was performed in 29, the Alvarez technique in two, and grafting in two. During the follow-up, 43 reinterventions were performed. Isthmus diameter/descending aorta diameter at the diaphragmatic level and repaired site diameter/descending aorta diameter at the diaphragmatic level were measured. Group A: the isthmus diameter/descending aorta diameter at the diaphragmatic level index was 0.92 +/- 0.08 and the repaired site diameter/ descending aorta diameter at diaphragmatic level index was 0.90 +/- 0.05. Twenty-three patients were assessed by means of three-dimensional magnetic resonance angiography, which revealed two late stenosis (one in a 10-year-old patient with an end-to-end anastomosis performed previously, and another in an 18-year-old patient with a proximal and distal obstructed conduit). Group B: the isthmus diameter/descending aorta diameter index was 0.84 +/- 0.1 and the repaired site diameter/ descending aorta diameter index was 0.82 +/- 0.11. Eleven patients were assessed by means of three-dimensional magnetic resonance angiography, which revealed five stenosis indexes (0.53-0.73) surgically corrected before the age of 2 months, four with an initial technique based on end-to-end anastomosis and one with a graft. Our results support the influence of young age, the use of end-to-end anastomosis and grafts in recoarctation and their late influence on recurrent recoarctation. The patients in group A were discharged in childhood or adulthood after periodic follow-up every 5 years with magnetic resonance angiography for 18 years with results within the normal range, while patients in group B required longer follow-up.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.