Abstract

The verification and validation (V&V) of the Serpent 2 Monte Carlo code for 3-D reactor dosimetry applications is being carried out at VTT. Two code-to-code computational benchmark cases were calculated by MCNP and Serpent 2. The computational efficiency of different variance reduction techniques was appraised. The validation part currently includes two experimental benchmarks from the SINBAD database: the Pool Critical Assembly-Pressure Vessel Facility (PCA); and the H.B. Robinson-2 (HBR-2) Pressure Vessel Dosimetry Benchmark. All simulations replicate the benchmark source specifications at pin level thanks to the development of a flexible, geometry-independent, fixed source definition for reactor dosimetry applications. Good agreement was found in all benchmark cases.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.