Introduction A suitable protocol to ensure rapid processing of smears for on-site immediate assessment (OSIA) is not available in Sri Lanka. The objective of this study was to validate the processing method of fine needle aspirates (FNA) for OSIA. Methodology Thirty five FNA obtained were processed as follows. The smear prepared from the first needle pass was fixed in 95% ethyl alcohol and stained with freshly prepared Harris haematoxylin for one minute each and assessed for adequacy of cellularity. It was then fixed for 20 minutes in the same fixative and stained by the Papanicolaou staining protocol (PSP). The smear prepared from the second needle pass was routinely processed and stained by PSP. Both smears were assessed by three histopathologists (A, B and C) independently and blind to the processing method for quality indicators, including air drying (ADpresence/ absence), nuclear differentiation(NDclarity of visibility of chromatin pattern as 1- poor, 2-intermediate and 3-clear,) and cytoplasmic clarity (CC-cell outline and clarity as 1-poor, 2- intermediate and 3-clear). Final quality of smear for reporting was categorized as satisfactory for reporting (absent AD and ND 2-3, CC 2-3), unsatisfactory but can report (absent AD and ND 1-2, CC 1-2) and unsatisfactory, cannot report (presence of AD and ND1, CC1). Statistical analysis was done using chi-square test. Results Of the 35 OSIA smears, pathologist A, B and C found (35/35) 100%, (26/35) 74.29%, and (28/35) 80% to be satisfactory for reporting, and (0/35) 0%, (1/35) 2.86%, and (1/35) 2.86% unsatisfactory for reporting. Of the 35 routinely processed smears, pathologist A, B and C found (29/35) 82.9%, (24/35) 68.6% and (16/35) 45.7% to be satisfactory for reporting: (4/35)11.4%, (4/35)11.4% and (3/35)8.6% to be unsatisfactory for reporting. Conclusion No significant difference (p< 0.05) was found by the three pathologists in the quality parameters of the smears from the two processing methods thus, validating the one minute processing method as comparable to the routine processing method.

Highlights

  • A suitable protocol to ensure rapid processing of smears for on-site immediate assessment (OSIA) is not available in Sri Lanka

  • The smear prepared from the first needle pass was fixed in 95% ethyl alcohol and stained with freshly prepared Harris haematoxylin for one minute each and assessed for adequacy of cellularity

  • The smear prepared from the second needle pass was routinely processed and stained by PSP

Read more

Summary

Introduction

A suitable protocol to ensure rapid processing of smears for on-site immediate assessment (OSIA) is not available in Sri Lanka. Validation of fine needle aspiration smear processing method for onsite immediate assessment Introduction A suitable protocol to ensure rapid processing of smears for on-site immediate assessment (OSIA) is not available in Sri Lanka.

Objectives
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.