Abstract

This paper describes an experimental investigation of the flow through an anatomically accurate model of the left nasal passage of a healthy adult male. Flow visualization, pressure loss and particle image velocimetry (PIV) measurements are reported. The data obtained from these tests is used to validate a computational fluid dynamics method. For a typical mesh of about one million tetrahedral cells, the flow rate versus pressure drop characteristic can be modeled to within 6%. Laminar flow conditions predominate at resting breathing rates, but even at higher breathing rates, the assumption of laminar flow does not appear to reduce greatly the accuracy of the predictions. Favorable comparison has been obtained between the PIV measurements and numerical predictions. The flow in the post-nasal space and naso-pharynx is dominated by a separation at the distal end of the nasal floor, a streamwise vortex and a large region of recirculating flow that forms along the inner wall of the naso-pharynx. Good agreement between the measurements and predictions in this downstream region of the flow gives confidence in the fidelity of the predictions upstream in the nasal cavity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.