Abstract

We present a new method for replicating the skull and occlusal surface with an accurate physical model that could be used for planning orthognathic surgery. The investigation was made on 6 human skulls, and a polyvinyl splint was fabricated on the dental cast of the maxillary dentition in each case. A cone beam computed tomogram (CBCT) was taken of each skull and a three-dimensional replica produced. The distorted dentition (as a result of magnification errors and streak artefacts) was removed from the three-dimensional model and replaced by new plaster dentition that was fabricated using the polyvinyl splint and a transfer jig replication technique. To verify the accuracy of the method the human skulls and the three dimensional replica model, with the new plaster dentition in situ, were scanned using a laser scanner. The three-dimensional images produced were superimposed to identify the errors associated with the replacement of the distorted occlusal surface with the new plaster dentition. The overall mean error was 0.72 and SD was (0.26) mm. The accuracy of the method encouraged us to use it clinically in a case of pronounced facial asymmetry.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.