Abstract

Background In patients with acute ST-segment elevation myocardial infarction (STEMI), recent clinical guidelines recommend that primary percutaneous coronary intervention (PCI) should be performed within 90 min of first medical contact or 45 min after admission in cathlab. The Door-to-Balloon time (D2B) is widely used to measure the performance of interventional centres. Aim of the study To analyze the time to reperfusion in a consecutive series of STEMI patients referred for primary PCI, and to evaluate the clinical accuracy of D2B in primary PCI. Methods From January 2007 to March 2008, 177 patients were admitted within 12 hours of a STEMI in our institution, and 87 were referred for a direct coronary angiography for primary PCI (47 by mobile medical emergency unit, 40 by the emergency department of the institution). Results The median time from first medical contact to balloon inflation (M2B) was 135 min [IQR 112–183]. Recommended times were fulfilled in a minority of patients (M2B < 90 min: 9%, <120 min: 34%). Median cathlab D2B was 51 min [IQR 44–65], and was less than 45 min in 34% of patients. No differences for times to reperfusion within cathlab were found between in- and off-time hours. M2B and D2B were unavailable in 23 patients (26%), because of a spontaneous TIMI 3 flow reperfusion without indication for immediate PCI in 20 patients, contra-indication for PCI in two (distal occlusion, culprit vessel diameter less than 2 mm), and failure in occlusion crossing by the guide-wire in one patient. In contrast, first medical contact- or door-to-reperfusion times, assessed by a TIMI 3 flow without no-reflow in culprit artery, were available in 95% of patients, and were shorter than M2B or D2B, respectively. Conclusion Although it is a feasible and reproducible process performance measure, D2B time is weakly associated with the outcome of the interventional reperfusion strategy in acute STEMI. This measure should be associated with an outcome performance measure, such as the rate of TIMI 3 flow achieved by primary PCI, or replaced by the Door-to-TIMI 3 flow reperfusion time.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.