Abstract
A Compact Airborne Spectrographic Imager-2 (CASI) dataset was used for detecting mortality and vegetation stress associated with a new forest disease. We first developed a multilevel classification scheme to improve classification accuracy. Then, the CASI raw data were transformed to reflectance and corrected for topography, and a principal component (PC) transformation of all 48 bands and the visible bands and NIR bands were separately conducted to extract features from the CASI data. Finally, we classified the calibrated and corrected CASI imagery using a maximum likelihood classifier and tested the relative accuracies of classification across the scheme. The multilevel scheme consists of four levels (Levels 0 to 3). Level 0 covered the entire study area, classifying eight classes (oak trees, California bay trees, shrub areas, grasses, dead trees, dry areas, wet areas, and water). At Level 1, the vegetated and non-vegetated areas were separated. The vegetated and nonvegetated areas were further subdivided into four vegetated (oak trees, California bay trees, shrub areas, grasses) and four non-vegetated (dead trees, dry areas, wet areas, and water) classes at Level 2. Level 3 identified stressed and non-stressed oak trees (two classes). The ten classes classified at different levels are defined as final classes in this study. The experimental results indicated that classification accuracy generally increased as the detailed classification level increased. When the CASI topographically corrected reflectance data were processed into ten PCs (five PCs from the visible region and five PCs from NIR bands), the classification accuracy for Level 2 vegetated classes (non-vegetated classes) increased to 80.15 percent (94.10 percent) from 78.07 percent (92.66 percent) at Level 0. The accuracy of separating stressed from non-stressed oak trees at Level 3 was 75.55 percent. When classified as a part of Level 0, the stressed and non-stressed were almost inseparable. Furthermore, we found that PCs derived from visible and NIR bands separately yielded more accurate results than the PCs from all 48 CASI bands.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.