Abstract
The concept of pseudocapacitance is explored as a rapid and universal method for the state of health (SOH) determination of batteries and supercapacitors. In contrast to this, the state of the art considers the degradation of a series of full charge/discharge cycles. Lithium-ion batteries, sodium-ion batteries and supercapacitors of different cell chemistries are studied by impedance spectroscopy during lifetime testing. Faradaic and capacitive charge storage are distinguished by the relationship between the stored electric charge and capacitance. Batteries with a flat voltage–charge curve are best suited for impedance spectroscopy. There is a slight loss in the linear correlation between the pseudocapacitance and Ah capacity in regions of overcharge and deep discharge. The correct calculation of quantities related to complex impedance and differential capacitance is outlined, which may also be useful as an introductory text and tutorial for newcomers to the field. Novel diagram types are proposed for the purpose of the instant performance and failure diagnosis of batteries and supercapacitors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.