Abstract

A method has been developed to obtain an accurate estimate of the mean ionization of energetic, heavy charged particles using a device which has small stopping power. A sample of the frequency distribution of energy losses in each of n identical proportional counters is obtained. This information is treated by selecting the smallest of the n pulses and using this smallest pulse to represent the mean ionization of the particle. The experimental results are compared with Landau's theory of the statistical fluctuations in the specific ionization of charged particles.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.