A new instrumentation mode has been put in place in order to determine the overflow rate of five complex CSOs of the system in Sélestat (French), which are subject to self monitoring. 3D and 1D models have made it possible to predict the shapes of the water lines and suggest a location for the ultrasound sensors. In order to validate the instrumentation principle, three overhead sensors were placed on a weir. The overflow laws suggested are of the type Q(overflow) = a1h1b1 + a2h2b2 + a3h3b3. Early results of the overflow rate that have been obtained by applying the law are close to 10 % of the flow measured in the physical test bench. On the actual site, the ultrasound sensors were assembled on a rail covering the entire weir in order to be able to change their position in future after models calibration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.