Abstract

A UPLC-MS/MS method was developed for the simultaneous determination of paeoniflorin, naringin, naringenin and glycyrrhetinic acid in rat plasma. A Waters BEH C(18) column was used with a gradient mobile phase system of methanol-water containing 2 mM ammonium acetate. The analysis was performed on a positive ionization electrospray mass spectrometer via multiple reaction monitoring (MRM). One-step protein precipitation with acetonitrile was used to extract the analytes from plasma. The limits of quantification were 9.800 ng/ml for paeoniflorin, 5.100 ng/ml for naringin, 5.200 ng/ml for naringenin and 10.60 ng/ml for glycyrrhetinic acid, respectively. The intra- and inter-day precision (relative standard deviation, RSD) ranged 4.9-12% and 2.8-13%, respectively. The accuracy (relative error, RE) was from -7.3% to 7.5% at all quality control (QC) levels. The validated method was applied to a pharmacokinetic study in rats after oral administration of Si-Ni-San decoction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.