Abstract
A simple design procedure is proposed for seismic retrofitting of existing structures using viscoelastic dampers (VEDs) based on the uniform damping ratio (UDR) concept to make full use of each damper. The UDR concept states that the equivalent damping ratios, which represent the energy dissipation capacities of the dampers, are the same for each installed VED. The stiffness and damping characteristic parameters of the damped structure can be formally decoupled using UDR-based derivations, which simplify the determination of the VEDs’ parameters. The generalized single-degree-of-freedom method and pushover analysis are adopted for a fast estimation of the seismic response of the damped elastoplastic structure. Taking the response reduction ratio as the design target, a seismic retrofit design procedure is proposed based on the UDR concept to meet the performance demand. Finally, a six-story frame is adopted to illustrate the proposed design method. The dynamic analysis results show that the seismic responses of the structure are well-controlled, as expected, and that the installed VEDs are used effectively. The conclusion can be drawn that the UDR-based design method for retrofitting an existing structure using VEDs is rational and effective.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.