Abstract

In the multilayer conductor, the inner layers have higher impedance than the outer layers. As a result, the current concentrates in the outer layers. Our early study showed that its AC losses were reduced to one-tenth by making the current of each layer uniform. From such a point of view, a trial to realize the uniform current distribution was made by adjusting the winding pitches of high-temperature superconducting (HTS) tapes layer by layer. A 1 m long conductor was fabricated, where the inner layer had longer winding pitch than the outer layer. Experimental results showed that the currents flowing in individual layers were almost the same and that this conductor had lower AC losses than the nonuniform current distribution conductor.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.