Abstract
Inverse force determination is commonly used to determine input forces when they are not directly measurable. If transfer functions are measured with the source component attached, the inversely determined forces are, by definition, blocked forces. The primary advantage of using blocked forces is that the receiving structure may be modified and blocked forces, in theory, are unchanged. In this research, blocked forces are determined for a plastic engine cover connected to a base plate and a compressor attached to two different structures. At lower frequencies, blocked forces are determined using routine approaches where phase is included in both transfer function and operational response measurements. At high frequencies, it is demonstrated that predictions are improved if phase is ignored and blocked forces are assumed to be uncorrelated with respect to each other. It is also shown that the uncorrelated blocked forces are still valid even when changes are made to the receiving structure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.